The single place for ARMAC's numbers. Other pages link here rather than repeating them, so a figure only has to be changed in one place.
Last checked against the code and site measurements: 7 November 2026 (code commit 1e3f995).
Water
| Item | Value | Source |
| Tank | Aquaplate corrugated steel, nominal 30,300 L | Supplier |
| Tank internal diameter | about 3.44 m, so about 95 L per cm of depth | Measured |
| Full water depth | 2.94 m (internal height 3.08 m, 14 cm freeboard) | Measured |
| Usable water | about 27,500 L (full tank down to the 0.05 m dry cutoff) | Calculated |
| Mains refill | about 15 L/min through the float valve | Measured |
| Reduced flow | 147 L/min | House water meter |
| High flow | 217 L/min | House water meter |
| Continuous run, full tank, reduced flow | about 187 minutes (just over 3 hours) | Calculated |
| Continuous run, full tank, high flow | about 127 minutes (just over 2 hours) | Calculated |
| Shed cooling | 5 flat-fan nozzles (1.1 mm), about 5 L/min; gravity-fed from the tank through 12 mm copper when the pump is off | Design |
Pump and fuel
| Item | Value |
| Pump | Garpen WP3DELHPS: 11 hp diesel, electric start, 3-inch single-impeller high-pressure pump |
| Maker's figures | maximum head 70 m (720 kPa), maximum flow 630 L/min |
| Bench test (2-inch outlets) | about 50 m head at 130 L/min; 45 m head at 300 L/min |
| Fuel tanks | 13 L plus a 24 L reserve tank (with level sender), in parallel through a T barb |
| Fuel use | about 2 L per hour, so about 17 hours from both tanks together |
Sprinklers and pipework
| Item | Value |
| Sprinklers | 13: 3 VYRSA-60 dual-nozzle impact sprinklers (3.6 mm and 2.4 mm nozzles) and 10 Pope heavy-duty impact sprinklers |
| Risers | 20 mm copper for the VYRSA-60s, 15 mm copper for the Popes |
| Feeder pipe | 100 m of DN50 (63 mm outside diameter) blue-line polypipe, buried 250-350 mm deep |
| Shed header | DN50 copper; DN20 reduced-flow and recirculation branches; 12 mm shed-cooling line |
Power
| Item | Value |
| Pump and shed battery | Fullriver HC44, 12 V 44 Ah, 560 cold-cranking amps |
| Charger | Victron Blue Smart IP65, 10 A, in the house; float about 13.5 V |
| House-to-shed power cable | two-core, 10 AWG (confirmed) |
| AR1 (Module 2) backup | separate 12 V 22 Ah gel battery (the one originally supplied with the pump) |
Gel injection
| Item | Value |
| Status | Built, not yet tested (boosterless design) |
| Gel | Barricade, 15.2 L on hand |
| Dosing pump | Huiji DN009 (Dosatron type), dial about 5% |
| Branch flow | about 2,000 L/h (33 L/min), set with a needle valve |
| Target concentration | about 1.4%; first trial planned at about 0.6% |
| Flow needed | reduced flow only: the constriction creates the pressure difference that drives the dosing pump |
Autonomous mode thresholds (AR3)
| Condition | Action |
| Water at or below 0.05 m | Dry cutoff: everything off, including shed cooling |
| Water 0.05-0.30 m | Gel priority: pump on, reduced flow, gel on; shed cooling still allowed |
| Water 0.30-0.50 m | Water-saving cycle: sprinklers 3 min on, 8 min off, whatever the temperature |
| Warm-up, outside 60-75 °C | Sprinklers 3 min on, 7 min off |
| Warm-up, outside 75-80 °C | Sprinklers 5 min on, 3 min off |
| Warm-up, outside above 80 °C | Continuous, high flow |
| Start of cool-down | Once outside has reached 60 °C: outside 5 °C below its peak and inside 2 °C below its peak |
| Cool-down, outside above 80 °C | Continuous, reduced flow |
| Cool-down, outside 70-80 °C | Sprinklers 3 min on, 5 min off |
| Cool-down, outside 60-70 °C | Sprinklers 3 min on, 8 min off |
| Cool-down, outside 60 °C or below | Sprinklers stop |
| Shed, inside 47 °C (after falling below 45 °C) | 1-minute cooling pulse; continuous if pulses start less than 2 minutes apart |
| Shed, inside above 60 °C | Continuous shed cooling |
| Battery at or below 12.0 V | Intermittent cycles use the recirculation valve, never restarting the pump |
| Battery above 12.0 V | Pump stopped and restarted only for cycles with more than 15 minutes off |
| No battery reading from AR1 for 5 minutes | Intermittent cycles use the recirculation valve |
| All temperature sensors failed for 1 minute | Timed fallback sequence, 5 minutes per stage (see Autonomous Fire Defence Algorithms) |
| Tank gauge failed | Level estimated from the flow meters; the last measured flow assumed if the flow meter has also failed (147 L/min reduced, 217 L/min high, until measured) |
Manual (dashboard) limits (AR1)
| Item | Value |
| Time ON / Time OFF settings | 0-30 minutes, set with - and + buttons (1 minute per tap) |
| Pump-cycling sprinkler mode | allowed only above 12.25 V and with both times over 10 minutes; otherwise the recirculation valve is used |
| Pump stop check | 45 seconds after a stop command |
Communications and mode timings
| Item | Value |
| RS-485 link (AR1-AR3) | 9,600 baud; every message framed and checked with a CRC-8 checksum |
| AR3 status to AR1 | every 2 seconds |
| AR1 status and heartbeat to AR3 | every 5 seconds |
| AR2 sensor data to AR3 | UDP over AR2's own WiFi, several times a second |
| Switch to the backup link | after 15 s without status from AR3 |
| AR3 enables its end of the backup link | after 10 s of RS-485 silence |
| Return to RS-485 | after 60 s of steady RS-485 |
| AR1 stops the heartbeat | after 5 minutes without its MQTT connection |
| AR3 enters Autonomous mode | after 5 minutes without a heartbeat |
| AR3 hands back to the dashboard | about 15 seconds after the heartbeat returns |
| Command acknowledgement | resent after 300 ms if not acknowledged, up to 3 times |
Pump starting by ARMAC (AR3, BYPASS mode)
| Item | Value |
| Fuel solenoid | held on by the pump latch relay; switched on 1 s before cranking |
| Attempts | up to 5 |
| Crank time | 2 s on the first attempt, up to 5 s after that (stops early when oil pressure appears) |
| Rest between attempts | 20 s |
| Running confirmed | oil pressure held for 5 s after cranking |
| No cranking | in the first 20 s after AR3 starts |
Code
| Board | Lines |
| AR1 | 3,462 |
| AR2 | 994 |
| AR3 | 3,050 |
| Total | 7,506, plus the Home Assistant configuration |