ARMAC grew over two years, and its design changed a great deal on the way - ideas that looked good turned out otherwise, and better ones emerged. That story is kept here as a dated record. These notes describe the system as it was at the time they were written, so they often differ from the system as it is now; the current description is in the other sections of this wiki.
The development notes
| Notes | Covers |
|---|---|
| Part A | Description, development stages, fire threat and defence decisions, sprinkler layout, the five modes of action, pipe connections, plumbing, the tank and pump layout |
| Part B | The pump shed and its plumbing, the water control system, the pump, pump-shed protection and ventilation, the tank, copper risers, anti-siphon control, flow and pressure requirements, extending run time, the intermittent spray mode |
| Part C | The electronics and control systems, in six parts: control modules and modes; relays, pins and wiring; sensors; Autonomous operation and fallbacks; resilience and protection; programming and testing |
| Gel dosing | The boosterless gel design (now also in The Gel Injection System) |
| Gel alternatives | Gel injection approaches considered and not adopted |
Development history by subject
- The water system: tank, pump, feeder pipe and flow modes
- Sprinklers and pipework
- Power
- Gel injection: approaches considered
- Sensors
- The electronics
- Autonomous mode as first designed
- The 2026 refinements
How the design evolved
- One Arduino in the house drove the shed relays and read the sensors over a long multicore cable, with a Raspberry Pi running Home Assistant. Electrical noise - especially from the pump's starter - made readings unreliable and relays switch by themselves.
- Two Arduinos sharing the relay lines - one in the house, one in the shed, through diodes - so the shed could act alone. It suffered from signal collisions and cable noise.
- The present design: sensors and relays in the shed, run by AR2 and AR3; AR1 in the house as the link to Home Assistant over a two-wire RS-485 link, with a backup serial link added later; a pump latch relay so resets can't start or stop the pump; a sensor-simulation test system (TestSys).
- Hardening (mainly 2026): hardware watchdogs on all boards, connection self-restarts, restart safety (a restart keeps Autonomous mode), CRC-8 message checking, sensor-failure fallbacks restored, tank and flow calibration against the house water meter, the optocoupler fix for the pressure switches, and ARMAC's own pump start sequence.
About these notes
The development notes are kept as an archive, unchanged apart from a note at the top of each page pointing to the current description. A 2026 review of the earlier wiki, which led to its rebuilding in the present form, recorded 93 places where the old pages had fallen behind the system as built.
<< Commissioning checks | | Development history: the water system >> |Table of Contents>